R14 Series Wall-Mounted RO Systems

Three models for flow rates to 5400 GPD, available with brass and stainless steel fittings. Fully assembled and ready for installation.

r14-wm

R14-03-BWM System

Standard Features

  • Stainless steel wall mount frame
  • Stainless steel pressure vessels
  • Webtrol multi-stage centrifugal pump
  • Automatic inlet valve
  • Low-pressure shut-off with automatic restart
  • Tank level input
  • Pretreatment interlock input
  • Adjustable recycle line
  • Pre-filter pressure gauges
  • Pump discharge pressure gauge (liquid-filled)
  • Flow meter for product water
  • Flow meter for reject water
  • Check valve for product water
  • Sample valve for product water
  • On / off switch

 

Options

  • Product water float switch
  • Whole house option*

*Includes 300 gallon tank, product water float switch and repressurization pump with built-in controls.

Applications

  • Whole house
  • Ice makers
  • Labs
  • Beverages
  • Coffee shops
  • Restaurants

Specifications

Feed water connection

1" FNPT

Product water connection (1800 & 3600 GPD)

1/2" tube

Product water connection (5400 GPD)

5/8" tube

Reject water connection (all R14 models)

1/2" tube

Feed water pressure requirement (minimum)

10 PSIG

Drain requirement (maximum)

10 GPM

Electrical requirement

230VAC/60hz

Amps (1800 & 3600 GPD)

6

Amps (5400 GPD)

9

Models

All models feature membrane sizes of 4" x 40" and typical rejection of 98%.

Dimensions on all models are 41" x 51" x 18".

Model Number

Fittings & Valves

GPD

Pump (HP)

Recovery (adjustable)

Number of Membranes

Feed Water Required * (GPM)

Ship Wt.

R14-01-
WM

SS

1800

1

15%-75%

1

2.5

200

R14-01-BWM

Brass

1800

1

15%-75%

1

2.5

200

R14-02-1WM

SS

3600

1

25%-75%

2

5

250

R14-02-BWM

Brass

3600

1

25%-75%

2

5

250

R14-03-1WM

SS

5400

1.5

35%-75%

3

7.5

300

R14-03-BWM

Brass

5400

1.5

35%-75%

3

7.5

300

*At 50% recovery.

NOTES: Performance specifications are based on 77 degree feed water, 3 SDI or less, TDS below 1000 and pH of 8. Individual membrane productivity and rejection rates are based on membrane manufacturer's specifications. Chlorine reduction and other pretreatment may be required. Systems are designed for use with municipal and well water.